Omni Engine Room
Home ] Up ] Compressor ] Condenser ] [ Omni Engine Room ] Hot Gas Defrost Evaporator ] Blast Freezer Controller ] Air Defrost Evaporator ] Ladder Logic ]

Key Benefits of the Omni Engine Room Controller:

Omni Compressor Portion:

bulletControls up to 5 compressors with one or two suction pressures.
bulletControls screw, recips, or rotary compressors in any combination.
bulletAutomatically sequences compressors to their most efficient combination to save energy.
bulletAutomatically keeps the compressors operating near full capacity to save energy.
bulletControls up to 2 different suction control set points at different times of day.
bulletStarts, stops, loads, and unloads compressors.
bulletSuction pressure control within 1 PSIG of the set point.
bulletUnloads compressors as high discharge safety pressure is approached.
bulletDischarge pressure shuts down on high discharge safety.
bulletDisplays compressor suction set point at whatever value you choose.
bulletDisplays current compressor suction operating pressure.
bulletDisplays compressor suction deadband at whatever value you choose.
bulletDisplays compressor suction minimum operating pressure set point.
bulletDisplays compressor manual or automatic control status.
bulletDisplays acceptable power outage time for auto restart.
bulletDisplays daily pressure offset times to control 2 separate daily suction set points.
bulletDisplays the compressor sequence and load percent capacity status.
bulletAlarms on safety control set point violations.
bulletAlarms on high suction trap liquid level and shuts down compressors of affected stage.
bulletMonitors your ammonia sniffer and shuts down compressors if leak is in the eng. room.
bulletAdjusts for non-linear slide valve capacity.
bulletLogs compressor run time hours and alerts for planned maintenance.
bulletMonitors system kWh usage.
bulletSimple for operator to change compressor control parameters.

Omni Condenser Portion:

bulletMonitors and displays ambient temp, relative humidity, discharge pressure and condensate liquid temp.
bulletFloats head pressure to lowest optimum operating pressure to save energy.
bulletControls up to 8 water pumps or fans.
bulletCalculates and displays ambient Wet Bulb Temp.
bulletDisplays and controls on difference between dry bulb and wet bulb temps.
bulletHas manual or automatic operation feature, displays difference between actual and saturation pressure , letting you know if air is in system.
bulletAllows operator to make changes to the pump and fan sequence.
bulletAllows operator to set the minimum operation discharge pressure set point.
bulletAutomatically raises discharge pressure set point for defrost cycle.
bulletHas adjustable dead band and step delay set point to avoid excessive fan cycling.
bulletShuts down compressors when high discharge safety pressure is reached.
bulletSimple for operator to change all condenser control parameters.
bulletMinimum pump operation temp protects against freeze-ups.

Omni Ladder Logic Portion:

bulletLadder Logic portion can be used for miscellaneous control, such as pump packages, lighting, floor warming, battery chargers, water chemistry control, etc.
bulletOMNI has 16 digital inputs and 16 analog inputs that can be used to control 16 digital outputs using ladder logic.
bulletAnalog and digital inputs from compressor and condenser portion can also be used in logic.
bulletLadder logic can use counting in logic.
bulletLadder logic can use delays and time of day in logic.
bulletLadder logic can use separately displayed adjustable set points in logic.
bulletLogic is written in easy to use English language tables.
bulletThree pages of logic tables are available in password protected region.
bullet16 internal flags and 16 counters are available for use in logic.